Fluke 28 II EX

Note : Harga dapat berubah sewaktu-waktuAuthorized Distributor

Now there’s one intrinsically safe digital multimeter (DMM) you can use in IIC (gas), in Zone 1 and 2 and IIIC (dust), Zone 21 and 22. Whether you work in petroleum, chemical, or pharmaceutical environments, all the test and troubleshooting power you need is packed into the most rugged intrinsically safe (IS) DMM Fluke has ever built. The Fluke 28 II Ex is also waterproof, dust-proof and drop-proof. You’ll be equipped to handle any situation, inside and outside of hazardous zones, without compromising compliance or measurement performance

ntrinsic safety plus regulatory approvals

The 28 II Ex carries Ex certifications from the world’s
leading certification bodies.

28 II Ex I.S. Certifications

  • IECEx Ex ia IIC T4 Gb, Ex ia IIIC T130 °C Db, I M1 Ex ia I Ma

28 II Ex safety and regulatory compliance

  • ISA-82.02.01
  • CAN/CSA-C22.2 No. 61010-1-04 /UL61010-1:2004, and TUV 61010-1:2001
  • CE

Extreme ruggedness

The Fluke 28 II Ex is the most rugged IS DMM you can buy.

  • A completely sealed, IP67 rated case
  • Withstands drops up to 10 feet or 3 meters (with holster)
  • Dustproof per IEC60529 IP6x
  • Waterproof per IEC60529 IPx7
  • Meets IEC Overvoltage Electrical Safety Standard No. 61010-1:2001
    • Measurement Category III, 1000V, Pollution Degree 2
    • Measurement Category IV, 600V, Pollution Degree 2

Reversible holster for added protection of the display when not in use

Basic Accuracy Specifications
Accuracy specifications are show as +/- (% of reading + number of digits)
DC voltage
Range 0.1 mV to 1000 V
Accuracy ±0.05 % + 1
AC voltage
Range: 0.1 mV to 1000 V
Accuracy: ±0.7 % +4
DC current
Range: 0.1 μA to 10 A
Accuracy: ±0.2 % + 4
AC current
Range: 0.1 μA to 10 A
Accuracy: ±1.0 % + 2
Resistance
Range: Range: 0.1 Ω to 50 MΩ
Accuracy ±(0.2 % + 1)
Conductance
Range: 60.00 nS
Accuracy: ± (1.0 % + 10)
Diode Test
Range: 2.0 V
Accuracy: ± (2.0 % + 1)
Duty Cycle
Range: 0.0 % to 99.9 %
Accuracy: Within ±(0.2 % per kHz + 0.1 %) for rise times <1 µs
Display counts
6000 counts/19,999 counts in high-resolution mode
Capacitance
Range: 10 nF to 9999 μF
Accuracy: ± (1.0 % + 2)
Frequency
Range: 0.5 Hz to 199.99 kHz
Accuracy: ± (0.005 % + 1)
Temperature
Range: -200 °C to +1090 °C (-328 °F to +1994 °F)
Accuracy: ± (1.0 % + 10) °C [± (1.0 % + 10) °F]
Peak Capture
Record transients up to 250 us
Min/Max/Avg Recording
Display signals up to approximately 100 ms
Safety Specifications
Safety certifications:
ATEX
II 2 G Ex ia IIC T4 Gb
II 2 D Ex ia IIIC T130 °C Db
I M1 Ex ia I Ma
NEC-500
Class I, Div 1, Groups A-D, 130 °C
IEXEx
Ex ia IIC T4 Gb
Ex ia IIIC T130 °C Db
Ex ia I Ma
GOST R Ex (Pending)
Overvoltage protection: Measurement Category III, 1000V, Pollution Degree 2
Measurement Category IV, 600V, Pollution Degree 2
IP rating: IP67