Fluke 106

Note : Harga dapat berubah sewaktu-waktuAuthorized Distributor

The Fluke 106 digital multimeter is made to fit the way you work! It is designed to fit in the palm of your hand and go with you no matter where your job takes you.

  • Voltage, resistance, continuity, capacitance
  • Input terminal for ac and dc current measurements to 10 A and current
  • Data hold

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])

Model Name Description
Fluke 106 Includes:
  • Fluke 106 Palm-sized Digital Multimeter
  • Tl75 Hard Point Test Lead Set
  • 2 AAA Batteries (Installed)
  • User’s Manual
Fluke 106/i400E Kit Includes:
  • Fluke 106 Digital Multimeter
  • Fluke i400E AC Current Clamp
  • Tl75 Hard Point Test Lead Set
Clips
AC220 AC220 SureGrip™ Alligator Clips
AC280 AC280 SureGrip™ Hook Clips
AC283 AC283 SureGrip™ Pincer Clips
AC285 AC285 SureGripTM Alligator Clips
AC87 AC87 Heavy Duty Bus Bar Clip Set
AC89 AC89 Heavy Duty Insulation Piercing Test Clip
Test Probes
TP38 TP 38 Slim Reach Test Probe Set
TP1 TP1 Slim Reach Test Probe Set
TP2 TP2 Slim Reach Test Probe Set
TP220 TP220 SureGrip™ Industrial Test Probes
TP4 TP4 Slim Reach Test Probe Set
TP74 TP74 Lantern Tip Test Probe Set
TP80 TP80 Electronic Test Probe Set
Current Clamps
Fluke i400E Fluke i400E AC Current Clamp
Cases and Holsters
C100 C100 Universal Carrying Case
C12A C12A Meter Case
C195 C195 Case
C800 C800 Meter and Accessory Case
C25 C25 Large Soft Case for DMMs
CAMO-C25 Camouflage Carrying Case
Test Leads, Probes and Clips
TL80A Fluke TL80A Basic Electronic Test Lead Kit Includes:
  • One pair (red, black) each 1 meter long silicone test lead set, alligator clip and probe tip extender
  • C75 soft carrying case
  • One year warranty
Pressure
PV350 PV350 Pressure Vacuum Module
Temperature
80T-150UA 80T-150U Universal Temperature Probe
80TK 80TK Thermocouple Module
Accuracy Specifications
Function Range Resolution Accuracy
AC Volts1 6.000 V 60.00 V 600.0 V 0.001 V 0.01 V 0.1 V 1.0 % + 3
DC Volts 6.000 V 60.00 V 600.0 V 0.001 V 0.01 V 0.1 V 0.5 % + 3
AC Millivolts 600.0 mV 0.1 mV 3.0 % + 3
Diode Test2 2.000 V 0.001 V 10 %
Resistance (Ohms) 400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5% + 3
Capacitance3 50.00 nF 500.0 nF 5.000 μF 50.00 μF 500.0 μF 1000 μF 0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5
Frequency4 Hz (10 Hz – 100 kHz) 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz NA
Duty Cycle4 1 % to 99 % 0.1 % NA
AC Current (40 Hz to 200 Hz) 4.000 A 10.00 A 0.001 A 0.01 A 1.5 % + 3
DC Current 4.000 A 10.00 A 0.001 A 0.01 A 1.5 % + 3
1. All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified. 2. Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA. 3. Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range). 4. All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
Function Overload Protection Input Impedance (Nominal) Common Mode Rejection Ratio Normal Mode Rejection Ratio
AC Volts 600 V 1 >10 MΩ <100 pF 2 >60 dB at dc, 50 Hz or 60 Hz
AC Millivolts 600 mV >1M, <100 pF >80 dB at 50 Hz or 60 Hz
DC Volts 600 V 1 >10 MΩ <100 pF >100 dB at dc, 50 Hz or 60 Hz >60 dB at 50 Hz or 60 Hz
1. 6 x 105 V Hz Max 2. For mV (AC), input impedance is approximately 1 MΩ.
General Specifications
Maximum Voltage Between any Terminal and Earth Ground 600 V
Display (LCD) 6000 counts, updates 3/sec
Battery Type 2 AAA, NEDA 24A, IEC LR03
Battery Life 200 hours minimum
Temperature
Operating 0 °C to 40 °C
Storage -30 °C to 60 °C
Relative Humidity
Operating Humidity Non-condensing when <10°C ≤90 % at 10 °C to 30 °C; ≤75 % at 30 °C to 40 °C
Operating Humidity, 40 MΩ Range ≤80 % at 10 °C to 30 °C; ≤70 % at 30 °C to 40 °C
Altitude
Operating 2000 m
Storage 12,000 m
Temperature Coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse Protection for Current Inputs 11A, 1000V Fast Fuse, Fluke specified part only
Size (HxWxL) 142 mm x 69 mm x 28mm
Weight 200 g
IP Rating IEC 60529: IP 40
Safety IEC 61010-1: 600 V CAT III, Pollution Degree 2
Electromagnetic Environment IEC 61326-1: Portable
Electromagnetic Compatibility Applies to use the Korea only. Class A Equipment (Industrial Broadcasting and Communication Equipment)1
1. This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes.