Fluke 787

Note : Harga dapat berubah sewaktu-waktuAuthorized Distributor

Double Your Power

A maintenance and calibration tool that will be at home in every instrumentation technician’s tool box, the Fluke 787 ProcessMeter™ combines a DMM and a Loop Calibrator in one rugged, handheld tool, for about what you would expect to pay for a loop calibrator alone. Based on the trusted Fluke 87 DMM, the 787 adds the ability to measure, source, and simulate dc loop current with 0.05% accuracy and 1 microamp resolution.

  • DMM and loop calibrator in one tool
  • Clear LCD with backlight; 4,000 counts (30,000 counts for dc current)
  • Externally accessible battery for easy battery changes.
  • 1000V overload protection on V, ohms, frequency.
  • 150V overload protection on mA, backed up by 440 mA 1000V fuse.
  • 25% Manual Step plus Auto Step and Auto Ramp on mA output.

Fluke combined the DMM you trust with the loop calibrator you need.
The Fluke 787 ProcessMeter™ puts a complete troubleshooting solution in the palm of your hand. Get in touch with more information, faster and easier with the newest member of the Fluke 80 Series, the 787 ProcessMeter. The 787 gives you the measurement capabilities you expect from our rugged, reliable DMMs plus the ability to source, simulate, or measure dc current with 1 microamp resolution and accuracy of 0.05%. Put it all together and you have the ideal tool for troubleshooting and calibrating current loop applications. So if you’re tired of always tracking down a calibrator, lugging around two tools and switching back and forth, get the single best solution for doubling your power. The 787 ProcessMeter from Fluke.

Current Measurement
Range:  0-1 A
Resolution:  1 mA
Accuracy:  0.2% + 2 LSD
Range:  0-30 mA
Resolution:  0.001 mA
Accuracy:  0.05% + 2 LSD
Current Sourcing
Range:  0-20 mA or 4-20 mA
Resolution:  0.05% of span
Drive Capability:  500 Ω @ 24 mA
Frequency
 to 19.999 kHz, 0.005% + 1 LSD
Continuity
 Beeps for resistance < 100 ohms
Voltage measurement
Range:  0-1000 V AC or DC
Resolution:  0.1 mV to 1.0 V
Accuracy:  0.1% Rdg + 1 LSD (VDC)
Resistance measurement
 to 40 MΩ, 0.2% + 1 LSD
Diode test
 2.4 V shows diode voltage drop
Environmental Specifications
Operating Temperature
 -20 ºC to 55 ºC
Storage Temperature
  -40 ºC to 60 ºC
Humidity (Without Condensation)
 95% up to 30 ºC
 75% up to 40 ºC
 45% up to 50 ºC
 35% up to 55 ºC
Temperature Coefficient
 0.05 x (specified accuracy) per ºC (for temperatures < 18 ºC or > 28 ºC)

Reviews


There are no reviews yet.

Be the first to review “Fluke 787”